Taiwan Cheng Tung Industrial Co., Ltd
Product Name:
RC Capacitor (Spark Suppression)
Description:
Outline Drawing:
Features:
Specification:
․Base specification: IEC 33(CO)77 A.C.motor capacitors. ․Climatic Category: In accordance with DIN40040 GPF. ․Rated Voltage: 250~450V.AC 50/60Hz ․Capacitance Range: 0.1~1.0uF ․Capacitance Tolerance: K(±10%) ․Withstand Voltage: (a).Between terminals:1.5 x rated voltage for 10s. ․Insulation Resistance: (a).Between terminals: ․Dry Heat Resistance: In accordance with IEC 68-2-2 test Ba. ․Cold Resistance: In accordance with IEC 68-2-1 test Aa. ․Humidity Resistance: In accordance with IEC 68-2-3 test Ca. ․Endurance: Place the capacitor in the thermostatic oven
JIS C4908 capacitors for electrical apparatus.
G=Minimum limit temperature:-40℃
P=Maximum limit temperature:+85℃
F=Humidity category:average relative
humidity ≦75%,95% for 30days per year;
continuously,85% for the remaining days;
occasionally.
(b).Between terminals and case:2 x rated voltage
+1000V (minimum 1500V) for 60s.
This test occasional self-healing breakdown
are allowed.
≧30x103MΩ for C≦0.33uF.
≧10x103MΩ /uF for C > 0.33uF.
Measured at 100V.DC 60s.and 20℃.
(b).Between terminals and case:≧10x103MΩ.
Measured at 100V.DC 60s.and 20℃.
Conditions
Test temperature:Maximum limit temperature.
Test duration:16hrs.
Test criteria
(a).Appearance:No visible damage and no leakage.
(b).Capacitance change:≦+2,-5% of the initial
value.
(c).Insulation resistance:≧10% of initial specified
value.
Conditions
Test temperature:Maximum limit temperature.
Test duration:2hrs.
Test criteria
(a).Appearance:No visible damage.
(b).Capacitance change:≦+3,-1% of the initial
value.
Conditions
Test temperature:+40℃
Relative humidity:90 to 95%
Test duration:21day.
Test voltage:(a).Without voltage.
(b).With rated voltage.
Test criteria
(a).Capacitance change:≦±4% of the initial value.
(b).Dissipation factor:≦0.5 x 10-3(0.05%) of
increased value.
(c).Insulation resistance:≧50% of initial specified
value.
in accordance with the condition of following:
Test A:Continuous endurance test.
Test temperature:Maximum limit temperature.
Test voltage:1.25 x rated voltage.
Test duration:1000±12hrs.
Test B:Intermittent endurance test.
Test temperature:Maximum limit temperature.
Test voltage:1.4 x rated voltage.2s. ON 2s.
OFF (15time / min.)
Test cycle(time):10 x 104
Test criteria
(a).Appearance:No visible damage and no leakage
3
(b).Capacitance change:≦±5% of the initial value.
(c).Dissipation factor:≦0.5 x 10-3(0.05%) of
increased value.
(d).Insulation resistance:≧50% of initial specified
value.
Safety Approval:
This is the detailed information for RC Capacitor (Spark Suppression), Series RC Units. The information includes model, name, description and specification for RC Capacitor (Spark Suppression), Series RC Units.
Please send your Inquiries for RC Capacitor (Spark Suppression), Series RC Units to us. We will contact you soon. Please also check out the related product categories below.